Talk to the team

MC80 HP UNIT

Capacity of 200 m3/h

Technical Overview

Manifold MC80 HP UNIT is a first stage pressure regulator intended for use in hospital pipeline system as a medical gas source.
MC80 HP UNIT contains two regulators with pressure relieve valves and it is connected to two various cylinder banks using high pressure hoses. When the cylinder bank, which has been connected for operation, has been emptied the other duty side is automatically connected.
It is equipped with pressure switches and pressure transmitters 4 – 20 mA.
Together with MC80 HP UNIT shall always be used gas alarm providing all alarms in compliance with the standard EN ISO 7396-1.
MC80 HP UNIT INCLUDES THE FOLLOWING COMPONENTS:
MC80 HP Manifold
FOR A COMPLETE MC80 HP UNIT MANIFOLD ADD:
Gas alarm (optional accessories)
High pressure hoses (optional accessories)

Product Information

Item No.
Description
0727321
Denomination: MC80 HP 2x1
Gas: O2
PRV: With pull-ring
Signalization: switch + 4-20 mA
0727322
Denomination: MC80 HP 2x1
Gas: Air
PRV: With pull-ring
Signalization: switch + 4-20 mA
0727323
Denomination: MC80 HP 2x1
Gas: N2O/O2
PRV: With pull-ring
Signalization: switch + 4-20 mA
0727321
Denomination: MC80 HP 2x1
Gas: O2
PRV: With pull-ring
Signalization: switch + 4-20 mA
0727322
Denomination: MC80 HP 2x1
Gas: Air
PRV: With pull-ring
Signalization: switch + 4-20 mA
0727323
Denomination: MC80 HP 2x1
Gas: N2O/O2
PRV: With pull-ring
Signalization: switch + 4-20 mA
Regional information available in your language at
GCEGROUP.COM

Technical

Gases
O2, Air, N2, N2O, CO2 (all medical gases)
Nominal flow
200 m3/h
Inlet nominal pressure
200 bar (20 000 kPa)
Outlet nominal pressure
12 bar (setting range 10–16 bar)
Inlet connection
W21,8×1/14"M
Outlet connection
G3/4"F
Pressure relive valve
17 bar
Pressure relive valve pipe dimension
ø 10 mm
Purge valve connections
W21,8×1/14"M + pipe ø 15 mm
Regulatory status
Complies with Medical Devices Directive 93/42/EEC
Complies with EN ISO 7396-1 (Central Gas Supply Systems)
Complies with EN 60601-1-2 (Electromagnetic compatibility)
present SIS HB 370 and HTM 02-01
Gases
O2, Air, N2, N2O, CO2 (all medical gases)
Nominal flow
200 m3/h
Inlet nominal pressure
200 bar (20 000 kPa)
Outlet nominal pressure
12 bar (setting range 10–16 bar)
Inlet connection
W21,8×1/14"M
Outlet connection
G3/4"F
Pressure relive valve
17 bar
Pressure relive valve pipe dimension
ø 10 mm
Purge valve connections
W21,8×1/14"M + pipe ø 15 mm
Regulatory status
Complies with Medical Devices Directive 93/42/EEC
Complies with EN ISO 7396-1 (Central Gas Supply Systems)
Complies with EN 60601-1-2 (Electromagnetic compatibility)
present SIS HB 370 and HTM 02-01

Technical Downloads