Talk to the team

MediCollect

Suction jar range of reusable jars that are air-tight, autoclavable and have an over flow valve

Technical Overview

The MediCollect Suction System is designed for use with a vacuum source (vacuum regulator, vacuum injector, etc.) in a hospital environment when collecting bodily liquids and secretions from patients during a medical procedure.
The primary line is a range of reusable jars that are air-tight, autoclavable and have an overflow valve
The disposable suction jars and bags
The bags are also available with Super Absorber which turns fluid into the gel which helps reduce the risk of contamination
Easy to clean
Safe, simple and easy to use
Fitted with overfill protection
Bag version fitted with a bacteria filter
Bag version available with Super Absorber

Gallery

Product Information

Item No.
Description
0727616
MediCollect Jar 1000, Size: 150×133, Weight (g): 290, Autoclave: 121°C / 20´, Durability: 30 Autoclave cycles
0727617
MediCollect Jar 2000, Size: 250×133, Weight (g): 432, Autoclave: 121°C / 20´, Durability: 30 Autoclave cycles
325111945
MediCollect Bag 1000, Size (HxWxD): 230×180×80, Weight (g): approx. 30
325111946
MediCollect Bag 2000, Size (HxWxD): 300×180×80, Weight (g): approx. 30
0727605
MediCollect Bag 1000 (SA*), Size (HxWxD): 230×180×80, Weight (g): approx. 35
0727606
MediCollect Bag 2000 (SA*), Size (HxWxD): 300×180×80, Weight (g): approx. 40
*super absorber
K291530
MediCollect 2000 Screw lid, Size (HxWxD): 302×135×130, Weight (g): 545, Autoclave: 121°C / 15´, Durability: 30 Autoclave cycles
K291540
MediCollect 1000 Screw lid, Size (HxWxD): 236×115×110, Weight (g): 340, Autoclave: 121°C / 15´, Durability: 30 Autoclave cycles
K291620
MediCollect 2000 Screw lid, Size (HxWxD): 302×135×130, Weight (g): 545, Autoclave: 134°C / 18´, Durability: 30 Autoclave cycles
K291619
MediCollect 1000 Screw lid, Size (HxWxD): 236×115×110, Weight (g): 340, Autoclave: 134°C / 18´, Durability: 30 Autoclave cycles
0727616
MediCollect Jar 1000, Size: 150×133, Weight (g): 290, Autoclave: 121°C / 20´, Durability: 30 Autoclave cycles
0727617
MediCollect Jar 2000, Size: 250×133, Weight (g): 432, Autoclave: 121°C / 20´, Durability: 30 Autoclave cycles
325111945
MediCollect Bag 1000, Size (HxWxD): 230×180×80, Weight (g): approx. 30
325111946
MediCollect Bag 2000, Size (HxWxD): 300×180×80, Weight (g): approx. 30
0727605
MediCollect Bag 1000 (SA*), Size (HxWxD): 230×180×80, Weight (g): approx. 35
0727606
MediCollect Bag 2000 (SA*), Size (HxWxD): 300×180×80, Weight (g): approx. 40
*super absorber
K291530
MediCollect 2000 Screw lid, Size (HxWxD): 302×135×130, Weight (g): 545, Autoclave: 121°C / 15´, Durability: 30 Autoclave cycles
K291540
MediCollect 1000 Screw lid, Size (HxWxD): 236×115×110, Weight (g): 340, Autoclave: 121°C / 15´, Durability: 30 Autoclave cycles
K291620
MediCollect 2000 Screw lid, Size (HxWxD): 302×135×130, Weight (g): 545, Autoclave: 134°C / 18´, Durability: 30 Autoclave cycles
K291619
MediCollect 1000 Screw lid, Size (HxWxD): 236×115×110, Weight (g): 340, Autoclave: 134°C / 18´, Durability: 30 Autoclave cycles
Regional information available in your language at
GCEGROUP.COM

Technical

Jar Material
Bag version: Polycarbonate (121°C), Without bag: Polycarbonate (121°C), Polysulfone (134°C)
Lid Material
Bag version: Polycarbonate, Thermoplastic Elastamer (TPE), Without bag: Polypropylene
Hose Nipple Material
Bag version: Polyethylene, Without bag: Nickel plated brass
Bag Material
Bag version: Polyethylene, Without bag: N/A
Anti-flow arrangement
Bag version: Integrated, Without bag: Ball float
Connector on source side
Bag version: Hose adapter for internal Ø9, Without bag: hose adapter
Connector on patient side
Bag version: Hose adapter for internal Ø9, Without bag: hose adapter
Max. applicable vacuum
-95 kPa (-950 mbar)
Min. applicable vacuum*
-20 kPa (-100 mbar)
*for the correct function of the overfilling protection device
Max. flow rate
Bag version: 70 l/min, Without bag: 100 l/min
Scale interval
Bag version: 50 ml (1000), 100 ml (2000), Without bag: N/A
Storage conditions
-40 ± 2°C to +60 ±5°C and 10 to 100% RH
Operating Conditions
-18 ± 2°C to +40 ±5°C and 40 to 70% RH
Regulatory status
Medical device in risk class I + accessory following Medical Device Regulation (EU) 2017/745
EN ISO 10079-3 – Medical Suction Equipment
Legal manufacturer
GCE, s.r.o., Žižkova 381, 583 01 Chotebor, Czech Republic
Jar Material
Bag version: Polycarbonate (121°C), Without bag: Polycarbonate (121°C), Polysulfone (134°C)
Lid Material
Bag version: Polycarbonate, Thermoplastic Elastamer (TPE), Without bag: Polypropylene
Hose Nipple Material
Bag version: Polyethylene, Without bag: Nickel plated brass
Bag Material
Bag version: Polyethylene, Without bag: N/A
Anti-flow arrangement
Bag version: Integrated, Without bag: Ball float
Connector on source side
Bag version: Hose adapter for internal Ø9, Without bag: hose adapter
Connector on patient side
Bag version: Hose adapter for internal Ø9, Without bag: hose adapter
Max. applicable vacuum
-95 kPa (-950 mbar)
Min. applicable vacuum*
-20 kPa (-100 mbar)
*for the correct function of the overfilling protection device
Max. flow rate
Bag version: 70 l/min, Without bag: 100 l/min
Scale interval
Bag version: 50 ml (1000), 100 ml (2000), Without bag: N/A
Storage conditions
-40 ± 2°C to +60 ±5°C and 10 to 100% RH
Operating Conditions
-18 ± 2°C to +40 ±5°C and 40 to 70% RH
Regulatory status
Medical device in risk class I + accessory following Medical Device Regulation (EU) 2017/745
EN ISO 10079-3 – Medical Suction Equipment
Legal manufacturer
GCE, s.r.o., Žižkova 381, 583 01 Chotebor, Czech Republic

Accessories

Item No.
Description
373234593
Suction hose adapter 9 mm
373234931
T-connection for suction
302532P
Hose; 0.35 m; ø 6/12
325113237
Silicone hose; 25m; 6×12
9435440
Silicone hose; 5m; 6×12
9435450
Silicone hose; 1m; 6×12
K006968
Manual vacuum stop device, non sterile for adults
0727435
Universal rail clamp 10 x 25 mm and 10 x 30 mm for T-slide application
373234593
Suction hose adapter 9 mm
373234931
T-connection for suction
302532P
Hose; 0.35 m; ø 6/12
325113237
Silicone hose; 25m; 6×12
9435440
Silicone hose; 5m; 6×12
9435450
Silicone hose; 1m; 6×12
K006968
Manual vacuum stop device, non sterile for adults
0727435
Universal rail clamp 10 x 25 mm and 10 x 30 mm for T-slide application

Technical Downloads

Find a distributor